sample after pre-test counselling following ANC, and performed the rapid test. Laboratory technicians routinely did the same test and returned reports of the test results to counsellors. Reports by the counsellors and the laboratory technicians were compared, and discordant reports in two groups were re-tested with the same rapid test kit using the same blood sample. Cause of discordance was detected in discussion with both groups. Of 563 blood samples tested by six trained VCCT counsellors and three laboratory technicians, 11 samples (2.0%) were reported positive in each group, however four discordant reports (0.7%) between the groups were observed, in which two positive reports and two negative reports by the counsellors were negative and positive by the laboratory technicians, respectively. Further investigation confirmed that all the reports by the counsellors were correct, and that human error in writing reports in the laboratory was a cause of these discordant reports
. These findings lead us the conclusion that the half-day training using the rapid and simple test was feasible for non-laboratory staffs to attain enough proficiency to implement VCCT services for PMTCT in resource-limited settings, and that human error was more likely to occur in laboratory before giving reports to counsellors.